Four Pole 100 AMP

Typical relays for 100 AMP are 4100NO-24A, 4100NO-24D, 4100NO-120A, and 4100NO-220A

4 Pole 100 AMP Mercury Relay

Click to Enlarge

Mercury to Metal Contactor Illustration

Click to Enlarge


Coil Data (Adding -11, -17, -18, etc. does not change the coil data)
Click Here for Relay Information and a list of Relay Part Number Possibilities

4100NC-12D

7 Ω

1,732 mA

20.8 VA

20.8 Watts

4100NC-24D

30.2 Ω

792 mA

19.2 VA

19.2 Watts

4100NC-48D

95 Ω

504 mA

24.4 VA

24.4 Watts

4100NC-125D

600 Ω

208 mA

26 VA

26 Watts

4100NC-24A

4 Ω

2,060 mA

49.6 VA

16.8 Watts

4100NC-120A

95 Ω

440 mA

52.8 VA

18.4 Watts

4100NC-208A

350 Ω

220 mA

45.6 VA

16.8 Watts

4100NC-240A

421 Ω

196 mA

47.2 VA

16.0 Watts

4100NC-480A

1,575 Ω

108 mA

52 VA

18.4 Watts

4100NO-24D

16.3 Ω

1,476 mA

35.6 VA

35.6 Watts

4100NO-48D

88 Ω

548 mA

26.4 VA

26.4 Watts

4100NO-125D

600 Ω

208 mA

26 VA

26 Watts

4100NO-24A

4 Ω

2,584 mA

62 VA

26.8 Watts

4100NO-120A

95 Ω

411 mA

65.6 VA

28.4 Watts

4100NO-220A

350 Ω

292 mA

64.4 VA

30 Watts

4100NO-277A

600 Ω

220 mA

60.8 VA

29.2 Watts

4100NO-480A

1,575 Ω

140 mA

67.2 VA

30.8 Watts

High Voltage
For UV Curing, and Various High Voltage applications. Available in Single Pole, Normally Open, and Normally Closed Units. The coils utilize 6-32 Wire Binding Screws, and the Contacts use Compression type terminals for #2 thru #8 A.W.G. wire.

4100NC-24D-6A

30.3 Ω

792 mA

19.2 VA

19.2 Watts

4100NC-120A-6A

95 Ω

600 mA

60 VA

23.6 Watts

4100NC-220A-6A

350 Ω

304 mA

66.8 VA

32.4 Watts

4100NO-12DH-6A

4 Ω

3,000 mA

36 VA

36 Watts

4100NO-24AH-6A

4 Ω

3,040 mA

72.8 VA

36.8 Watts

4100NO-24DH-6A

16.3 Ω

1,470 mA

35.6 VA

35.6 Watts

4100NO-120AH-6A

95 Ω

632 mA

76 VA

38 Watts

4100NO-220AH-6A

350 Ω

360 mA

79.2 VA

45.2 Watts


Ratings

  • 100NO Only
  • AC Resistive
    • 240 VAC @ 100 AMPS
    • 480 VAC @ 80 AMPS
    • 600 VAC @ 70 AMPS
  • Tungsten Lamp
    • 120 VAC @ 100 AMPS
  • Motor Loads
    • Single Phase
      • Not Recommended
  • 100NC or 100NOH
  • AC Resistive
    • 240 VAC @ 100 AMPS
    • 480 VAC @ 80 AMPS
    • 600 VAC @ 70 AMPS
  • AC Inductive
    (P.F. 0.4 or Greater)
    • 120 VAC @ 100 AMPS
    • 240 VAC @ 100 AMPS
  • General Purpose
    (P.F. 0.7 or greater)
    • NC 240 VAC @ 80 AMPS
    • NO(H) 240 VAC @ 100 AMPS
    • 480 VAC @ 80 AMPS
  • DC Resistive Heating
    • 48 VDC @ 100 AMPS
    • 125 VDC @ 50 AMPS
    • 250 VDC @ 30 AMPS
  • Tungsten Lamp
    • 120 VAC @ 100 AMPS
  • Motor Loads
    • Single Phase
      • 120 VAC @ 7.5 H.P.
      • 240 VAC @ 10 H.P.
    • Three Phase
      • 240 VAC @ 15 H.P.
      • 480 VAC @ 20 H.P.
  • S100NOH
  • AC Resistive
    • 240 VAC @ 100 AMPS
    • 480 VAC @ 100 AMPS
    • 600 VAC @ 80 AMPS
  • AC Inductive
    (P.F. 0.4 or Greater)
    • 120 VAC @ 100 AMPS
    • 240 VAC @ 100 AMPS
  • General Purpose
    (P.F. 0.7 or greater)
    • NC 240 VAC @ 100 AMPS
    • NO(H) 240 VAC @ 100 AMPS
    • 480 VAC @ 80 AMPS
  • DC Resistive Heating
    • 48 VDC @ 100 AMPS
    • 125 VDC @ 50 AMPS
    • 250 VDC @ 30 AMPS
  • Tungsten Lamp
    • 120 VAC @ 100 AMPS
  • Motor Loads
    • Single Phase
      • 120 VAC @ 7.5 H.P.
      • 240 VAC @ 10 H.P.
    • Three Phase
      • 240 VAC @ 15 H.P.
      • 480 VAC @ 20 H.P.
  • 100NOH-6A
  • AC Inductive
    General Purpose
    (P.F. 0.7 or Greater)
    • 3500 VAC @ 10 AMPS
    • 2500 VAC @ 15 AMPS
  • Motor Loads
    • Not Recommended

SpecSheets

UP
Previous